Jiangsu Relita Import & Export Co.,Ltd

Automatic Food Nitrogen Generator

National patent valve guarantees stable equipment operation. Air tank ensures stable system air consumption. Nitrogen buffer tank ensures stable system gas supply.

Send Inquiry
Product Details

Introduction of automatic food nitrogen generator

A complete PSA nitrogen generation system includes air compressor, air dryer, filters, air receiving tank, nitrogen generator/nitrogen making machine, air buffer tank, nitrogen buffer tank, etc. 

Working Principle of Nitrogen Producing System

When the process adopts lifting air, oxygen and nitrogen have different diffusion rate and adsorptive capacity to separate oxygen from nitrogen on carbon molecular sieve. When air is compressed to 0.8MPa, air source enters in pressure-swing adsorption tower for separation after being purified through dry and oil-water separation process (filter). Oxygen molecules are diffused and adsorbed in carbon molecular sieve under pressure. Non-adsorbed nitrogen is discharged from outlet of adsorption tower. Oxygen is desorbed, discharged and purged in adsorption tower under depressurization. Moreover, adsorbent can be recycled.


Specification Parameters

Condition

Brand New

Brand Name

RELITA

Control Mode

Intelligent Control

Production Rate

500sets/year

Voltage

220V/50HZ, the voltage can be as local demand

Technology

Pressure Swing Adsorption (PSA)

Life

10 years with proper maintenance

Key Words

Nitrogen Generator, Nitrogen Making Machine, High Purity Industry Nitrogen Generator

Certification

ISO9001, CE, SGS etc

Price

Negotiable

Payment term

TT, LC

RELITA can design a nitrogen generator that fits your particular requirements.


Main Features

1.  Advanced process flow directly reduces compressed air consumption.

2.   World famous molecular sieve ensures maximum energy-saving.

3.   Advanced load adaptation technology further saves energy.

4.   The most reliable air cleaning process ensures adsorbing efficiency and lifetime of molecular sieve.

5.   National patent valve guarantees stable equipment operation.

6.   Air tank ensures stable system air consumption.

7.   Nitrogen buffer tank ensures stable system gas supply.

8.   National patent compaction technology ensures long life of CMS.

9.   Long-distance supervision and control.

10. Professional technologies ensure reliable gas supply.

11.  Friendly human-machine interface.

3


Technical Parameters

Nitrogen Capacity: 3-3000Nm³/hr (20℃,101.325Kpa)

Nitrogen Purity: 95%-99.9995%

Nitrogen Pressure: 0.05-0.8Mpa (can custom-made)

Normal Nitrogen Dew Point: ≤-40℃(can custom-made)

Model

N2 Purity

%

N2 Capacity

Nm³/h

Air Consumption

m³/min

Dimensions

mm (L×W×H)

RLT-40

99

40

1.8

1900×1400×1800


99.5


2.0

2000×1450×1900


99.9


2.8

2100×1500×2050


99.99


3.7

2200×1500×2350


99.999


6.0

2600×1800×2550

RLT-50

99

50

2.1

2000×1500×1900


99.5


2.5

2050×1450×1850


99.9


3.3

2100×1500×2250


99.99


4.7

2500×1700×2500


99.999


7.5

2700×1800×2600

RLT-80

99

80

3.7

2100×1500×2000


99.5


4.0

2100×1500×2150


99.9


5.5

2500×1700×2550


99.99


7.5

2700×1800×2600


99.999


12.0

3200×2200×2800

RLT-100

99

100

4.6

2100×1500×2150


99.5


5.0

2200×1500×2350


99.9


7.0

2650×1800×2700


99.99


9.3

2750×1850×2750


99.999


15.0

3350×2500×2800

RLT-150

99

150

7.0

2450×1470×2400


99.5


7.5

2550×1800×2600


99.9


10.5

2750×1850×2750


99.99


14.0

3300×2500×2750


99.999


22.5

3500×3000×2900

RLT-200

99

200

9.3

2600×1800×2550


99.5


10.0

2700×1800×2600


99.9


14.0

3300×2500×2800


99.99


18.7

3500×2700×2900


99.999


30.0

3600×2900×2900

RLT-300

99

300

14.0

2700×1850×2700


99.5


15.0

3150×2150×2750


99.9


21.0

3500×2700×2900

RLT-500

99

500

23.3

3350×2500×2800


99.5


25.0

3500×2700×2900


99.9


35.0

3800×3000×3000

RLT-800

99

800

37.5

3600×2900×2900


99.5


40.0

3600×3000×2900


99.9


56.0

4000×3500×3000

RLT-1000

99

1000

47.0

3600×2900×2900


99.5


50.0

4000×3000×2900


99.9


70.0

4200×3550×3000

RLT-1500

99

1500

70.0

4000×3500×2900


99.5


75.0

4200×3500×2950


99.9


105.0

4500×3800×3000

RLT-2000

99

2000

94.0

4200×3500×3000


99.5


100.0

4300×3800×2950


99.9


140.0

5000×5000×3000

RLT-3000

99

3000

140.0

4500×3800×2950


99.5


150.0

4800×4800×3000


99.9


210.0

6000×6000×3000


Please Contact Us for More Models and Details of Nitrogen Generator!

1


Services

1, Engineering and Design 

RELITA engineers will design gas generating systems unique for your application and economic conditions.

2, Manufacturing 

RELITA custom builds & assembles systems to accommodate your gas generating application.

3, Installation & Commissioning 

RELITA experienced and highly skilled technicians can assist you with system installation, start-up and commissioning. Our staff can also provide on-site operational training.

4, Maintenance & Repair 

RELITA can provide regularly scheduled on-site maintenance checks to ensure your system functions at peak performance levels. RELITA can also quickly dispatch our technical staff to repair your system, when necessary.

 

FAQ of Nitrogen Generator

1.What is the floor space of nitrogen equipment?

Answer: Based on equipment specification;(Pre-case have indicated: nitrogen equipment roughly needs the same floor space compared with gas cylinder under same gas requirement).

2. Nitrogen equipment can be installed in the outdoor?

Answer: It can be installed in outdoor on condition that it have been added antifreeze,radiator, moisture proof devices; But most of nitrogen equipment is installed in the

indoor for saving cost.

3.Nitrogen equipment is safety?

Answer: Definitely! Nitrogen generator is a kind of air separation device under 

normal temperature, it can supply stable and continuous nitrogen gas; it doesn’t 

need any high-pressure cylinders and liquid cylinders which have potentially

dangerous; so we don’t need to worry about no-timely supply due to special 

circumstance.

4.The producing nitrogen is gaseous state or liquid state?

Answer: Our nitrogen equipment use PSA air separation technology under normal 

temperature, the temperature of nitrogen product is close to ambient temperature.

5.How long is the nitrogen equipment service life?

Answer: Generally speaking, industrial equipment service life is depend on daily 

maintenance; under normal maintenance, our equipment can well running for 

more than 10 years.


Hot Tags: automatic food nitrogen generator, suppliers, price, high quality, made in China
Related Products
Inquiry